Gas Equipment & Installation

Oleh: PT. Aneka Gas Industri  30/10/2009
Kata kunci: Gas, Medis

 Medical Supply Equipment

Central Cylinder Supply
The medical gases used in a hospital are life supporting element that gives direct influence in maintaining the life of a patient. Therefore, at the sections where the medical gases are used, the medical gas must be clean, highly pure and supplied under stable pressure.


Conventionally, a high pressure cylinder for medical use (high pressure gas cylinder) is directly taken into an operating room, ICU or ward, and used for medical care. However, there has been some problems in this system from the aspect of safety and hygiene, that is, danger such as a turnover a high pressure gas cylinder, gas leak from the cylinder and the inflammability of gases, hygienic management of gas cylinder itself, and necessity of enough care in handling high pressure gases.

The medical gas central piping system has been developed in order to eliminate those inconveniences. In this system, high pressure gas cylinders, compressors and vacuum pumps are centralized at one place in a hospital, and the gasses and the air are supplied to each section through piping. This system eliminates the danger at each section through piping where the gases are used and releases the complicated procedures for using the gases. However, there are some absolutely necessary conditions for this system as follows:
  • The pipe line should be used according to the gas type
  • Spontaneous interruption must not be allowed in gas supply
  • The high purity gas must be supplied from the medical gas outlet
  • A stable gas pressure must be maintained
To make these conditions complied with, there are legal regulations and standards.

Our medical gas system has cleared those regulations and standards as well as passing our strict company standards. The system has a thoroughgoing color coordination according to the kind of gas, an audio visual monitoring system capable of checking the situation, and a device to prevent cross connection at medical gas outlet based on the concept, “more safely” and “more securely”.

Medical air supply station
Medical air supply stations clean and purified compressed air from which impurities such as particles and Nitrogen Oxide have been removed. In addition, to prevent condensation in the piping, the air is dried using an air dryer.

Vacuum Supply Station
Oil rotary vacuum pumps which maintain a high suction pressure, supply a high degree of vacuum. The packaged unit combines receiver, bacterial filter and control cabinet providing space and labor saving. Furthermore, the supply station is provided with a monitoring system to monitor the operating condition and the supply situation at any time so as to provide a continuous, consistent, safe and reliable supply of medical gases.

Ancillary Equipment
To maintain a reliable supply of medical gases, it is necessary to establish a monitoring system which traces the flow of invisible gas from the source of supply through the piping to the section of gas use. The ancillary equipment which is connected to the medical gas outlet must have a high accuracy to control the medical gas flow correctly and ensuring performance to maintain this function. All of our outlet ancillary equipment, such as suction units, and humidifiers which are in direct contact with patients and medical gas measuring equipment, is designed and manufactured ensuring the user's safety and convenience.

Outlet Gas, Ceiling Module & Pendant
The medical gas outlet which the medical staff such as doctors and nurses use for daily medical care must be so designed as not to allow a cross connection to a different medical gas not intended.

The wall type being the main type, various types of outlets are available each of which is suitable for the medical treatment conditions in operating room, ICU, delivery room, immature baby’s room, etc.

Alarm System
To maintain a stable supply of medical gases, it is necessary to establish a monitoring system which surely traces the flow of invisible gas from the source of supply through piping to the section to use the gas.

We have been offering various monitoring systems which are possible to grasp the information of supply source such as the amount of gas remaining in the right and left banks of manifold.

Bedhead Unit
Our Bedhead unit is of a horizontal type integrating a variety of functions such as those doctors and nurses to make diagnosis and medical treatment and those for patient’s lighting and communication.

This unit is possible to install a required number of necessary equipments such as medical gas outlets, electric receptacles and nurse call slave units at a functional position, taking into account the size of ward, number of beds and their arrangement in a ward. In addition, we have a variety of types such as a concealed model with little exposure of equipment so as to ease the patient’s sense of oppression, a panel type with built in treatment lamps, and a type to create a comfortable space by indirect lighting.

Our flat type bedhead unit can be function as:
  • Helping doctor or nurse in conducting a diagnose
  • Light installation for the patient
  • Patient communication
Nurse Call
PT Aneka Gas Industri offers hospitals a choice of nurse call systems and nurse call stations to meet your goals for patient satisfaction.

Kata kunci: Gas, Medis